Power-On Failure Repair in Nairobi

Power-On Failure Repair in Nairobi

  • PSU Overhaul: Capacitor farms rebuilt to spec.

  • Standby Circuit Diagnosis: Fixes no-light conditions.

  • Soft Power Solutions: Eliminates relay chatter.

  • Surge Damage Recovery: Lightning protection bypassed.

  • Prologic Power Experts: 95% success rate.

  • Rapid Power Restoration: Back online same day.

Power-on failures range from dead standby to clicking relays. Swollen capacitors block rails; MOSFET shorts draw excess current. Prologic technicians load-test PSUs with variacs, graphing voltage curves. Nairobi brownouts bake electrolytic caps prematurely.

Feedback loops fail, causing overvoltage shutdowns.

Failure Patterns

No LED: primary fuse blown. Pulsing light: protection mode. Click-loop: shorted load.

Warm standby but no main power: relay coil open.

Diagnostic Approach

ESR meters test cap health. Curve tracers profile transistors. Ripple scopes reveal feedback issues.

Inrush limiters isolate cold-start faults.

Comprehensive Fixes

Capacitor sonic-welding prevents microphonics. Optocoupler swaps restore feedback. Snubber networks tame switching noise.

PFC boost diodes replaced.

Advanced Gear

Hipot testers verify isolation. Power analyzers measure PF. Thermal chambers accelerate aging tests.

Client Advantages

Stable 5-year power delivery. Silent operation. Energy-efficient post-repair.

Failure Type Root Cause Time Cost (KES)
Dead Standby Fuse/cap 2 hrs 5,000-10,000
Click Loop MOSFET short 3 hrs 8,000-15,000
No Main Power Relay fail 2.5 hrs 6,000-12,000
Overvoltage Feedback IC 4 hrs 12,000-20,000
Brownout Trip PFC stage 3.5 hrs 10,000-18,000

Warranty: 12 months power-related.

Protection Strategies

Whole-house surge suppressors. UPS backups. Annual cap inspections.